Allows machinists to establish temporary datums instantly. ⚡ Step-by-Step Initial Setup & Calibration

The standard method to enter the "Setup" mode is by pressing the 8 key ten times. However, many users report this does not work on their A163 unit. This is because the A163 often has hidden, unlabeled physical buttons on the circuit board behind the front panel overlay.

in the internal parameter settings. Setting this to "0" doubles the count for diameter reading. Centering (Divide by 2) Function

Email directly (service@heidenhain.com) with "Request: Anilam Mini Wizard A163 manual" and the serial number (on back of unit). They often email PDFs within 24 hours for legacy products.

Anilam Mini Wizard A163 is a classic Digital Readout (DRO) system used for manual machining on mills and lathes. Finding the "hot" manual often means looking for setup codes like the "8" key trick to enter parameters.

If the DRO reads double the actual travel (e.g., moving 0.200 inches shows 0.400 inches), the scale resolution is incorrectly configured. The fix is to enter the setup mode: Press the '8' key ten times repeatedly to access the configuration menu. If unsuccessful, you may need to open the case and locate the dip switches on the circuit board, adjusting them to match the resolution of your new scale.

: This is often caused by dirty glass scales. Clean the internal glass with isopropyl alcohol to restore reading accuracy.

BACK TO TOP